1.
Trop Doct ; 54(1): 30-34, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37788356

RESUMO

Retained needle fragments can occur in intravenous drug user (IVDU), which can lead to significant morbidity and mortality. The aim of present study is to give an overview of our institutional experience and treatment protocol followed for such patients. IVDU with retained fragment of fractured needle were taken from the patient presenting in Emergency, Medicine and CTVS departments with history of IVDU, from January 2019 to December 2020. Six patients were found with retained broken needles. Detailed history, examination and investigations were done. The needle was removed under local anaesthesia successfully in all patients. IVDU with retained broken needle poses risk for catastrophic complications along with possibility of local complications. A systematic approach in managing such patients is required. These broken needles can be successfully retrieved as day care procedure. Lastly, IVDUs with fractured needles pose threat to the caregivers who should take caution to avoid iatrogenic injury.


Assuntos
Usuários de Drogas , Abuso de Substâncias por Via Intravenosa , Humanos , Abuso de Substâncias por Via Intravenosa/complicações , Protocolos Clínicos